  • Q What is the main advantage of a Magnetic Safety Agitator over a conventional mechanically sealed agitator?

    A The primary advantage is absolute containment. By eliminating the mechanical shaft seal—the most common potential leak point—it guarantees zero leakage. This makes it the only safe choice for handling extremely hazardous, toxic, expensive, or sterile fluids.
  • Q When should I choose a Side Entry Agitator?

    A Choose a Side Entry Agitator primarily for large-volume blending in storage tanks or ponds (e.g., for crude oil, fuels, chemicals, or water). It's ideal when top or bottom mounting isn't feasible and is excellent for preventing stratification and maintaining homogeneity with high energy efficiency.
  • Q What is the key benefit of a Bottom Entry Agitator design?

    A Its key benefit is freeing up the vessel top head. This is crucial for tanks requiring frequent cleaning, multiple top nozzles, or complete drainage. The design also minimizes bottom sedimentation and offers excellent stability due to a short shaft.
  • Q How do I select the right impeller type for my mixing process?

    A Impeller selection depends on your primary process objective (e.g., blending, suspending solids, dispersing gases). Common types include axial flow impellers (e.g., hydrofoils) for efficient bulk blending and radial flow impellers (e.g., Rushton turbines) for high shear dispersion. We provide expert selection support based on your fluid properties and process goals.
  • Q Can your agitators handle high-viscosity or non-Newtonian fluids?

    A Yes. For high-viscosity, shear-thinning, or pasty materials, we recommend specific impeller designs like helical ribbons or anchors paired with robust Top Entry drives. These create the necessary combination of bulk motion and wall scraping for effective mixing.
  • Q What sealing options are available, and how do I choose?

    A We offer a full range, from packing glands (for simple, non-hazardous services) to single and double mechanical seals (for volatile or hazardous fluids). For the ultimate in safety, the Magnetic Drive requires no seal. Selection is based on fluid hazard, pressure, temperature, and regulatory requirements.